AESTUVER D2 fire protection element

AESTUVER D2 fire protection element

Lightweight cement-bonded concrete board reinforced with glass fibre, for escape routes.

Application: For covering concrete troughs beside railway tracks, or as a replacement for timber plank covers.

 

Specifics

Category Value / Description
Characteristic values
Equilibrium moisture content (65% rel.) ≈ 7% (at 20 °C and 65% RH, according to DIN EN ISO 12570)
Alkalinity (pH value) ≈ 12
Approvals
Building material class EN 13501-1 — Non-combustible, A1
Fire resistance class I 90 and E 90 (1)
Panel parameters and formats
Panel thickness 52.5 mm
Weight per m² (at 5% moisture content) 47 kg/m²
Panel format 1 250 × 625 mm
Other formats Thicknesses, formats and cutting to order
Dimensional tolerances
Width ± 1 mm
Thickness ± 2 mm
Maximum permissible traffic load
60 cm 12.5 kN/m²
80 cm 7.0 kN/m²
95 cm 5.0 kN/m²
100 cm 4.5 kN/m²
125 cm 2.8 kN/m²
Maximum permissible load (jump test)
Support width 100 cm
Jump height 82 cm
Test specimen 100 kg
Test report MFPA Leipzig, UB III/B-06-014
(1) Fire resistance ratings depend on the construction system and installation details.