Fermacell Firepanel A1

A1 classification for interior linings is increasingly required across Europe, especially for public buildings where dry construction methods are used. The reason lies in the harmonisation of fire protection tests and fire safety classifications, which has led to stricter national requirements for building materials and structural elements.
Fermacell Firepanel A1 has been designed specifically for these applications. A new composition and the use of non-combustible fibres have made this possible.

Specifics

Characteristic values
Gross density 1200 ± 50 kg/m³
Bending strength > 5.8 N/mm²
Equilibrium moisture at 65% relative humidity and 20°C air temperature 1.3%
Water vapour diffusion resistance factor (μ) 16
Thermal conductivity (according to DIN EN 12664) λ10,tr 0.38 W/mK
Expansion/shrinkage with a 30% change in relative humidity (20°C) 0.25 mm/m
pH value 7 – 8